概述
CBA系列的气液分离器可减少化学药剂输送以及晶片加工系统中的气泡。它们具有4英寸的内径,在气液分离过程中提供更大的表面积。它们可用于各种可连接的管道长度。它们具有可配置的接口连接方式和榫槽密封。可安装液位传感器。
![CBA气液分离器去除化学药剂供应过程中的气泡](https://cdn.wkfluidhandling.com/wp-content/uploads/cba-4a-connectable-pipes-300x298.jpg)
特点和优点
- 过程安全的PTFE和PFA液体通路
- 最高7公斤(100PSI)压力
- 最高100度
- 化学药剂输送以及晶片加工系统中的气液分离
- White Knight 泵独有的 榫和槽型密封件 技术是最可靠和可重复使用的
- 带螺纹连接的挤压式PFA管提供简单的安装和维护并且无需焊接
- 耐高压的能力为更快的工艺提供大流量
- 可达6升的型号
![White Knight 气液分离器 - 去除化学药剂供应过程中的气泡](https://cdn.wkfluidhandling.com/wp-content/uploads/cba_operation-diagram-with-sensor-lines-460x610.png)
操作
CBA系列的气液分离器可改变上升的流量减缓流体的流速,使得气泡在腔体内上升。当空气聚集在顶部时,液位下降直到下液位传感器检测到低液位信号并给排气阀发出打开信号,通过排气口释放空气。随着空气排出,液面上升,直到上液位传感器检测到高液位信号,并指示阀门关闭。
Debubbler Applications
Remove Bubbles After Pumps
Chemical enters the debubbler through the stand tube. Level sensors 1 and 2 control the collected air volume in the debubbler. Collected air exits through the vent line.
![Debubbler Removing Bubbles After Pump](https://cdn.wkfluidhandling.com/wp-content/uploads/debubbler-removing-bubbles-after-pump-840x280.png)
![Debubbler Removing Bubbles After Pump](https://cdn.wkfluidhandling.com/wp-content/uploads/debubbler-remove-bubbles-after-pump-410x196.png)
Remove Bubbles Before Pumps
Chemical is pulled into the debubbler through the stand tube. Level sensors 1 and 2 control air collection level to purge the collected air, a vacuum is required to remove collected air. This can be achieved using a venturi-type vacuum.
![Debubbler Removing Bubbles Before Pump](https://cdn.wkfluidhandling.com/wp-content/uploads/debubbler-removing-bubbles-before-pump-840x280.png)
![Debubbler Removing Bubbles Before Pump](https://cdn.wkfluidhandling.com/wp-content/uploads/debubbler-remove-bubbles-before-pump-410x196.png)
Automate Drum Change
Level sensors 1 and 2 act to keep bubbles from the drums from continuing through to the pump. Level 3 indicates an empty drum. This can be used as an automatic drum switch or as a drum empty signal.
![Debubbler Automated Drum Change with Empty Signal](https://cdn.wkfluidhandling.com/wp-content/uploads/debubbler-automated-drum-change-with-empty-signal-1-840x466.png)
![Debubbler Automated Drum Change with Empty Signal](https://cdn.wkfluidhandling.com/wp-content/uploads/debubbler-automate-drum-change-with-empty-signal-410x210.png)