PFA 浸入式水箱加热器

概述

HFI Series immersion heaters are the perfect solution for heating harsh chemicals and DI water in tanks to constant temperature. Their PFA/PTFE wetted surfaces are ideal for use in high-purity applications where efficiency and chemical compatibility are of utmost importance. HFI heaters provide maximum power output and uniform heating while also limiting the volume of chemical needed. Their flexible, compact designs fit easily inside wet process baths, acid etch tanks, and other liquid heating applications. They are best suited for PVDF, PFA, and quartz tanks common to applications in semiconductor, solar, pharmaceutical, biomedical, and other high-purity industries.

Heateflex PFA 浸入式水箱加热器
PFA浸入式水箱加热器规格表
HFI系列订购说明獲取報價單本地經銷商
PFA Immersion Tank Heater Manual
流体加热器计算器

特点和优点

  • Ultrapure PTFE/PFA wetted surfaces
  • Maximum power in compact footprint
  • Reliable heating of harsh chemicals
  • Maximum 200°C heating capability
  • Fast temperature response and efficiency
  • Low watt density design for longer reliability
  • Each configuration capable of various voltage and wattage combinations
  • Compatible with international voltages
  • Integrate easily into most PVDF, PFA, and quartz wet process tanks
  • Sizes from 7×5 to 19×14 inch
  • Compact height of 1-5/8 inch
  • Hi-limit Type-J thermocouple
  • No N2 purge required

配置

  • Perforated top grid separates heater from items above. Perforated bottom grid separates heater from tank floor
  • 1/2-in raised legs
  • Thermal cut-off sensor for 72-240°C
  • Over-temperature thermocouple
  • Type-J process thermocouple
  • RTD process thermocouple
  • RTD over-temperature thermocouple
  • Platinum or embedded ground wire
  • Thermal Fuses
  • Longer 20-ft lead wire
  • PFA tubing on lead wires (10-ft)
  • Special Cut Grids
  • Air 200 and 300 Controller

规范

加热元件 Heateflex® Coil
润湿表面 PFA/PTFE
尺寸(LxW) 7x5 to 19x14 inch
高度 1-5/8 inch
瓦数 1.0 – 20 kW
电压 120 – 480 VAC
1 or 3 phase
温度 200°C (392°F)
温度准确度 ±0.1°C
效率 >99 %
接地线 Encapsulated
铅丝 15-ft

*All specifications depend on size, voltage, wattage, and customer utilization. See configuration instructions for sizing, capability, and compatibility.

獲取報價單本地經銷商

配置

Filter by:

Model Size Length Width Wattage Wattage Voltage Phase
HFI-0705-010-B-J-GE7 x 5 in751.0 kW0-1.9120 VAC1-Phase
HFI-0705-023-E-J-GE7 x 5 in751.7 kW0-1.9200 VAC1-Phase
HFI-0705-023-E-J-GE7 x 5 in751.9 kW0-1.9208 VAC1-Phase
HFI-0707-020-B-J-GE7 x 7 in772.0 kW2-3.9120 VAC1-Phase
HFI-0705-023-E-J-GE7 x 5 in752.1 kW2-3.9220 VAC1-Phase
HFI-0707-030-F-J-GE7 x 7 in772.1 kW2-3.9200 VAC1-Phase
HFI-0705-023-E-J-GE7 x 5 in752.3 kW2-3.9230 VAC1-Phase
HFI-0707-030-F-J-GE7 x 7 in772.3 kW2-3.9208 VAC1-Phase
HFI-0707-030-F-J-GE7 x 7 in772.5 kW2-3.9220 VAC1-Phase
HFI-0707-030-F-J-GE7 x 7 in772.8 kW2-3.9230 VAC1-Phase
HFI-0707-030-F-J-GE7 x 7 in773.0 kW2-3.9240 VAC1-Phase
HFI-0905-020-B-J-GE9 x 5 in952.0 kW2-3.9120 VAC1-Phase
HFI-0905-030-F-J-GE9 x 5 in952.1 kW2-3.9200 VAC1-Phase
HFI-0905-030-F-J-GE9 x 5 in952.3 kW2-3.9208 VAC1-Phase
HFI-0905-030-F-J-GE9 x 5 in952.5 kW2-3.9220 VAC1-Phase
HFI-0905-030-XX-J-GE9 x 5 in952.7 kW2-3.9380 VAC1-Phase
HFI-0905-030-F-J-GE9 x 5 in952.8 kW2-3.9230 VAC1-Phase
HFI-0905-030-XX-J-GE9 x 5 in953.0 kW2-3.9400 VAC1-Phase
HFI-0905-030-F-J-GE9 x 5 in953.0 kW2-3.9240 VAC1-Phase
HFI-0907-040-D-J-GE9 x 7 in973.3 kW2-3.9200 VAC1-Phase
HFI-0909-055-L-J-GE9 x 9 in993.4 kW2-3.9380 VAC1-Phase
HFI-0909-050-F-J-GE9 x 9 in993.5 kW2-3.9200 VAC1-Phase
HFI-0907-040-D-J-GE9 x 7 in973.6 kW2-3.9208 VAC1-Phase
HFI-0909-050-F-J-GE9 x 9 in993.7 kW2-3.9208 VAC1-Phase
HFI-0909-055-L-J-GE9 x 9 in993.8 kW2-3.9400 VAC1-Phase
HFI-0907-040-D-J-GE9 x 7 in974.0 kW4-5.9220 VAC1-Phase
HFI-0909-050-F-J-GE9 x 9 in994.2 kW4-5.9220 VAC1-Phase
HFI-0909-050-F-J-GE9 x 9 in994.6 kW4-5.9230 VAC1-Phase
HFI-0909-050-F-J-GE9 x 9 in995.0 kW4-5.9240 VAC1-Phase
HFI-0909-055-L-J-GE9 x 9 in995.5 kW4-5.9480 VAC1-Phase
HFI-1105-040-D-J-GE11 x 5 in1153.3 kW2-3.9200 VAC1-Phase
HFI-1107-050-F-J-GE11 x 7 in1173.5 kW2-3.9200 VAC1-Phase
HFI-1107-055-L-J-GE11 x 7 in1173.5 kW2-3.9380 VAC1-Phase
HFI-1105-040-D-J-GE11 x 5 in1153.6 kW2-3.9208 VAC1-Phase
HFI-1107-050-F-J-GE11 x 7 in1173.7 kW2-3.9208 VAC1-Phase
HFI-1107-055-L-J-GE11 x 7 in1173.8 kW2-3.9400 VAC1-Phase
HFI-1105-040-D-J-GE11 x 5 in1154.0 kW4-5.9220 VAC1-Phase
HFI-1107-050-F-J-GE11 x 7 in1174.2 kW4-5.9220 VAC1-Phase
HFI-1107-050-F-J-GE11 x 7 in1174.6 kW4-5.9230 VAC1-Phase
HFI-1109-070-F-J-GE11 x 9 in1194.8 kW4-5.9200 VAC1-Phase
HFI-1107-050-F-J-GE11 x 7 in1175.0 kW4-5.9240 VAC1-Phase
HFI-1109-070-F-J-GE11 x 9 in1195.2 kW4-5.9208 VAC1-Phase
HFI-1111-088-L-J-GE11 x 11 in11115.5 kW4-5.9380 VAC1-Phase
HFI-1107-055-L-J-GE11 x 7 in1175.5 kW4-5.9480 VAC1-Phase
HFI-1109-070-F-J-GE11 x 9 in1195.9 kW4-5.9220 VAC1-Phase
HFI-1111-088-L-J-GE11 x 11 in11116.1 kW6-7.9400 VAC1-Phase
HFI-1109-070-F-J-GE11 x 9 in1196.4 kW6-7.9230 VAC1-Phase
HFI-1109-070-F-J-GE11 x 9 in1197.0 kW6-7.9240 VAC1-Phase
HFI-1111-088-L-J-GE11 x 11 in11118.8 kW8-9.9480 VAC1-Phase
HFI-1305-045-L-J-GE13 x 5 in1352.8 kW2-3.9380 VAC1-Phase
HFI-1305-045-L-J-GE13 x 5 in1353.1 kW2-3.9400 VAC1-Phase
HFI-1305-050-F-J-GE13 x 5 in1353.5 kW2-3.9200 VAC1-Phase
HFI-1305-050-F-J-GE13 x 5 in1353.7 kW2-3.9208 VAC1-Phase
HFI-1305-050-F-J-GE13 x 5 in1354.2 kW4-5.9220 VAC1-Phase
HFI-1309-068-L-J-GE13 x 9 in1394.3 kW4-5.9380 VAC1-Phase
HFI-1305-045-L-J-GE13 x 5 in1354.5 kW4-5.9480 VAC1-Phase
HFI-1305-050-F-J-GE13 x 5 in1354.6 kW4-5.9230 VAC1-Phase
HFI-1309-068-L-J-GE13 x 9 in1394.7 kW4-5.9400 VAC1-Phase
HFI-1307-070-F-J-GE13 x 7 in1374.8 kW4-5.9200 VAC1-Phase
HFI-1309-070-F-J-GE13 x 9 in1394.8 kW4-5.9200 VAC1-Phase
HFI-1305-050-F-J-GE13 x 5 in1355.0 kW4-5.9240 VAC1-Phase
HFI-1309-070-F-J-GE13 x 9 in1395.2 kW4-5.9208 VAC1-Phase
HFI-1307-070-F-J-GE13 x 7 in1375.2 kW4-5.9208 VAC1-Phase
HFI-1309-070-F-J-GE13 x 9 in1395.9 kW4-5.9220 VAC1-Phase
HFI-1307-070-F-J-GE13 x 7 in1375.9 kW4-5.9220 VAC1-Phase
HFI-1311-090-Q-J-GE13 x 11 in13116.2 kW6-7.9200 VAC3-Phase
HFI-1309-070-F-J-GE13 x 9 in1396.4 kW6-7.9230 VAC1-Phase
HFI-1307-070-F-J-GE13 x 7 in1376.4 kW6-7.9230 VAC1-Phase
HFI-1309-068-L-J-GE13 x 9 in1396.8 kW6-7.9480 VAC1-Phase
HFI-1311-090-Q-J-GE13 x 11 in13116.8 kW6-7.9208 VAC3-Phase
HFI-1311-110-L-J-GE13 x 11 in13116.9 kW6-7.9380 VAC1-Phase
HFI-1309-070-F-J-GE13 x 9 in1397.0 kW6-7.9240 VAC1-Phase
HFI-1307-070-F-J-GE13 x 7 in1377.0 kW6-7.9240 VAC1-Phase
HFI-1311-110-L-J-GE13 x 11 in13117.6 kW6-7.9400 VAC1-Phase
HFI-1311-090-Q-J-GE13 x 11 in13117.6 kW6-7.9220 VAC3-Phase
HFI-1311-104-E-J-GE13 x 11 in13117.9 kW6-7.9200 VAC1-Phase
HFI-1311-090-W-J-GE13 x 11 in13118.1 kW8-9.9380 VAC3-Phase
HFI-1311-090-Q-J-GE13 x 11 in13118.3 kW8-9.9230 VAC3-Phase
HFI-1311-104-E-J-GE13 x 11 in13118.5 kW8-9.9208 VAC1-Phase
HFI-1311-090-Q-J-GE13 x 11 in13119.0 kW8-9.9240 VAC3-Phase
HFI-1311-090-W-J-GE13 x 11 in13119.0 kW8-9.9400 VAC3-Phase
HFI-1311-104-E-J-GE13 x 11 in13119.5 kW8-9.9220 VAC1-Phase
HFI-1311-104-E-J-GE13 x 11 in131110.4 kW10-11.9230 VAC1-Phase
HFI-1311-110-L-J-GE13 x 11 in131111.0 kW10-11.9480 VAC1-Phase
HFI-1505-055-L-J-GE15 x 5 in1553.4 kW2-3.9380 VAC1-Phase
HFI-1505-050-F-J-GE15 x 5 in1553.5 kW2-3.9200 VAC1-Phase
HFI-1505-050-F-J-GE15 x 5 in1553.7 kW2-3.9208 VAC1-Phase
HFI-1505-055-L-J-GE15 x 5 in1553.8 kW2-3.9400 VAC1-Phase
HFI-1505-050-F-J-GE15 x 5 in1554.2 kW4-5.9220 VAC1-Phase
HFI-1505-050-F-J-GE15 x 5 in1554.6 kW4-5.9230 VAC1-Phase
HFI-1505-050-F-J-GE15 x 5 in1555 kW4-5.9240 VAC1-Phase
HFI-1505-055-L-J-GE15 x 5 in1555.5 kW4-5.9480 VAC1-Phase
HFI-1509-090-L-J-GE15 x 9 in1595.6 kW4-5.9380 VAC1-Phase
HFI-1509-090-L-J-GE15 x 9 in1596.3 kW6-7.9400 VAC1-Phase
HFI-1507-070-XX-J-GE15 x 7 in1576.3 kW6-7.9380 VAC1-Phase
HFI-1509-100-F-J-GE15 x 9 in1596.9 kW6-7.9200 VAC1-Phase
HFI-1507-070-XX-J-GE15 x 7 in1577 kW6-7.9400 VAC1-Phase
HFI-1509-100-F-J-GE15 x 9 in1597.5 kW6-7.9208 VAC1-Phase
HFI-1509-100-F-J-GE15 x 9 in1598.4 kW8-9.9220 VAC1-Phase
HFI-1509-090-L-J-GE15 x 9 in1599.0 kW8-9.9480 VAC1-Phase
HFI-1509-100-F-J-GE15 x 9 in1599.2 kW8-9.9230 VAC1-Phase
HFI-1511-120-O-J-GE15 x 11 in15119.9 kW8-9.9200 VAC3-Phase
HFI-1509-100-F-J-GE15 x 9 in15910.0 kW10-11.9240 VAC1-Phase
HFI-1511-113-W-J-GE15 x 11 in151110.2 kW10-11.9380 VAC3-Phase
HFI-1514-165-V-J-GE15 x 14 in151410.3 kW10-11.9380 VAC3-Phase
HFI-1514-150-Q-J-GE15 x 14 in151410.4 kW10-11.9200 VAC3-Phase
HFI-1511-120-O-J-GE15 x 11 in151110.7 kW10-11.9208 VAC3-Phase
HFI-1514-150-Q-J-GE15 x 14 in151411.2 kW10-11.9208 VAC3-Phase
HFI-1511-113-W-J-GE15 x 11 in151111.3 kW10-11.9400 VAC3-Phase
HFI-1514-165-V-J-GE15 x 14 in151411.4 kW10-11.9400 VAC3-Phase
HFI-1511-120-O-J-GE15 x 11 in151112.0 kW12-13.9220 VAC3-Phase
HFI-1514-150-Q-J-GE15 x 14 in151412.6 kW12-13.9220 VAC3-Phase
HFI-1514-150-Q-J-GE15 x 14 in151413.7 kW12-13.9230 VAC3-Phase
HFI-1514-150-Q-J-GE15 x 14 in151415.0 kW14-15.9240 VAC3-Phase
HFI-1514-165-V-J-GE15 x 14 in151416.4 kW16-17.9480 VAC3-Phase
HFI-1907-088-L-J-GE19 x 7 in1975.5 kW4-5.9380 VAC1-Phase
HFI-1907-088-L-J-GE19 x 7 in1976.1 kW6-7.9400 VAC1-Phase
HFI-1909-090-Q-J-GE19 x 9 in1996.2 kW6-7.9200 VAC3-Phase
HFI-1905-070-XX-J-GE19 x 5 in1956.3 kW6-7.9380 VAC1-Phase
HFI-1909-090-Q-J-GE19 x 9 in1996.8 kW6-7.9208 VAC3-Phase
HFI-1905-070-XX-J-GE19 x 5 in1957.0 kW6-7.9400 VAC1-Phase
HFI-1909-090-Q-J-GE19 x 9 in1997.6 kW6-7.9220 VAC3-Phase
HFI-1909-090-W-J-GE19 x 9 in1998.1 kW8-9.9380 VAC3-Phase
HFI-1909-090-Q-J-GE19 x 9 in1998.3 kW8-9.9230 VAC3-Phase
HFI-1911-135-V-J-GE19 x 11 in19118.5 kW8-9.9380 VAC3-Phase
HFI-1907-088-L-J-GE19 x 7 in1978.8 kW8-9.9480 VAC1-Phase
HFI-1909-090-Q-J-GE19 x 9 in1999.0 kW8-9.9240 VAC3-Phase
HFI-1909-090-W-J-GE19 x 9 in1999.0 kW8-9.9400 VAC3-Phase
HFI-1911-135-V-J-GE19 x 11 in19119.4 kW8-9.9400 VAC3-Phase
HFI-1911-150-Q-J-GE19 x 11 in191110.4 kW10-11.9200 VAC3-Phase
HFI-1911-150-Q-J-GE19 x 11 in191111.2 kW10-11.9208 VAC3-Phase
HFI-1911-150-Q-J-GE19 x 11 in191112.6 kW12-13.9220 VAC3-Phase
HFI-1914-205-V-J-GE19 x 14 in191412.8 kW12-13.9380 VAC3-Phase
HFI-1911-135-V-J-GE19 x 11 in191113.5 kW12-13.9480 VAC3-Phase
HFI-1911-150-Q-J-GE19 x 11 in191113.7 kW12-13.9230 VAC3-Phase
HFI-1914-205-V-J-GE19 x 14 in191414.2 kW14-15.9400 VAC3-Phase
HFI-1914-208-Q-J-GE19 x 14 in191414.5 kW14-15.9200 VAC3-Phase
HFI-1911-150-Q-J-GE19 x 11 in191115.0 kW14-15.9240 VAC3-Phase
HFI-1914-208-Q-J-GE19 x 14 in191415.6 kW14-15.9208 VAC3-Phase
HFI-1914-208-Q-J-GE19 x 14 in191417.5 kW16-17.9220 VAC3-Phase
HFI-1914-208-Q-J-GE19 x 14 in191419.2 kW18-19.9230 VAC3-Phase
HFI-1914-205-V-J-GE19 x 14 in191420.5 kW20-21.9480 VAC3-Phase
HFI-1914-208-Q-J-GE19 x 14 in191420.8 kW20-21.9240 VAC3-Phase