風囊泵 vs. 離心泵加熱槽循環
A White Knight PXASD060 bellows pump and Levitronix BPS600 centrifugal pump were run simultaneously in identical recirculation systems. The bath temperature was recorded eight hours. White Knight’s pump maintained a stable fluid temperature. The centrifugal pump heated the fluid bath significantly.