Overview
PL60 pumps are metal-free and feature PTFE/PFA fluid paths. They distribute chemicals at temperatures up to 100°C (212°F) and allow for air supply pressures up to 7 Bar (100 psi). They operate continuously throughout their two-year warranty. The pumps are capable of up to 60 L/min flow rates.
Features & Benefits
- Metal-free PTFE and PFA liquid path
- Leak-proof, machined design
- No elastomer O-rings, no leaks, never retorque
- No lubrication in shift mechanisms
- No electric motors, which generate heat
- Pneumatic Logic™ minimizes pulsation and vibration
- Various liquid connection options
- Safe, leak-free operation due to no-metal design
- Polypropylene heads, ceramic in air shuttle valve
- Minimal parts for durable design
- Class 100 cleanroom assembly, testing, and packaging
- Easy to install and service
- Proven reliable to 300 million+ cycles
- No preventative maintenance during two-year warranty
- A solenoid-driven option is also available
Operation
PL60 Operation

PSA060 Upgrade Operation

PSA060 pumps feature external shuttles that operate with a solenoid valve and end of stroke detection.
Supply Air
Exhaust Air
Ambient Air
Liquid Suction
Liquid Discharge
Temperature Limits
PL Series Temperatures

PSA Series Temperatures

Pump Comparisons
Performance
PL60 Performance

PSA060 Performance

Dimensions
PL60 Dimensions

PSA060 Dimensions

Specifications
Model |
PL60 |
|
---|---|---|
Warranty | 2 Years |
2 Years |
Max Flow Rate* | 60 lpm 15 gpm |
62.3 lpm 16.46 gpm |
Size of Air Connection | 1/4 or 3/8 in FNPT |
1/4 in FNPT |
Displacement Per Cycle* | 0.143 liters 0.038 gal |
0.178 liters 0.047 gal |
Cycles Per Minute* | ≤ 320 |
≤ 348 |
Weight | 5.6 kg 12.3 lb |
4.7 kg 10.36 lb |
Suction Lift* | 1 m (3 ft) |
3 m (10 ft) |
Sound Pressure** | 75.44 dB(a) 83.44 dB(a) |
73.11 dB(a) 82.50 dB(a) |
Sound Power** | 66.94 dB(a) 75.73 dB(a) |
64.29 dB(a) 74.11 dB(a) |
Max Pressure | 7 Bar (100 psi) |
7 Bar (100 psi) |
Max Temperature | 100°C (212°F) |
100°C (212°F) |
Fluid Path Materials | PTFE / PFA |
PTFE / PFA |
Non-Fluid Path Materials | PTFE / PFA / PP / ceramic |
PTFE / PFA / PP / ceramic |
Stroke Detection Options | Fiber optic with or without sensor, or solid state pressure switch |
|
Leak Detection Options | Fiber optic with or without sensor, or conductivity |
|
Electronic Control | Available |
|
Model |
PL60 |
*May vary depending on configuration. Suction lift diminishes over time. Recommended installation level less than 3 ft above source.
**dB Level at 60 psi 50CPM (top) and 60 psi maximum CPM (bottom). Sound Levels measured in accordance with ISO9614-2:1997.
Contact White Knight for details.