PFA浸入式水箱加熱器

概述

HFI Series immersion heaters are the perfect solution for heating harsh chemicals or DI water to constant temperatures in ultrapure tanks, including PVDF, PFA, and quartz tanks. Their PFA/PTFE wetted surfaces are ideal for use in high-purity applications where chemical compatibility is of utmost importance. HFI heaters utilize the Heateflex® element to provide high-efficiency heating with superior temperature control and maximum power output in a compact footprint. The heaters are available in various sizes that easily fit new and existing systems common to semiconductor, solar, MEMs, and other technological industries.

Heateflex PFA浸入式水箱加熱器
浸入式水箱加熱器規格表
浸入式水箱加熱器訂購說明獲取報價單本地經銷商
浸入式水箱加熱器用戶手冊
流體加熱器計算器

特點和優點

  • Ultrapure PTFE/PFA wetted surfaces
  • Reliable heating of harsh chemicals
  • Maximum power in compact footprint
  • Maximum 200°C heating capability
  • Fast temperature response and efficiency
  • Each configuration capable of various voltage-to-wattage combinations
  • Integrate easily into most PVDF, PFA, and quartz wet process tanks
  • Sizes for many tank dimensions
  • Compact height of 1-5/8 inch
  • Safety features include hi-limit sensor and encapsulated ground wire
  • No N2 purge required

Floor Grid 配置

  • Top grids separate heaters from wafer carriers and components to increase the available tank space
  • Bottom grids separate heaters from the tank floor
  • Available for all frame sizes
  • Adds 1/8 inch to height
Heateflex PFA浸入式水箱加熱器 Perforated Grids

*Shown with top and bottom grid.

規範

加熱元件 Heateflex® Coil
潤濕表面 PFA/PTFE
瓦數 1.0 – 20 kW
電壓 120 – 480 VAC
1 or 3 phase
尺寸 (LxW) 7x5 to 19x14 inch
高度 1-5/8 inch
溫度 200°C (392°F)
Hi-Limit Sensor Type-J thermocouple
接地線 Encapsulated
鉛絲 15-ft

*All specifications depend on size, voltage, wattage, and customer utilization. See configuration instructions for sizing, capability, and compatibility.

獲取報價單本地經銷商

配置

Filter by:

Model Size Length Width Wattage Wattage Voltage Phase
HFI-0705-010-B-J7 x 5 in751.0 kW0-1.9120 VAC1-Phase
HFI-0705-023-E-J7 x 5 in751.7 kW0-1.9200 VAC1-Phase
HFI-0705-023-E-J7 x 5 in751.9 kW0-1.9208 VAC1-Phase
HFI-0707-020-B-J7 x 7 in772.0 kW2-3.9120 VAC1-Phase
HFI-0705-023-E-J7 x 5 in752.1 kW2-3.9220 VAC1-Phase
HFI-0707-030-F-J7 x 7 in772.1 kW2-3.9200 VAC1-Phase
HFI-0705-023-E-J7 x 5 in752.3 kW2-3.9230 VAC1-Phase
HFI-0707-030-F-J7 x 7 in772.3 kW2-3.9208 VAC1-Phase
HFI-0707-030-F-J7 x 7 in772.5 kW2-3.9220 VAC1-Phase
HFI-0707-030-F-J7 x 7 in772.8 kW2-3.9230 VAC1-Phase
HFI-0707-030-F-J7 x 7 in773.0 kW2-3.9240 VAC1-Phase
HFI-0905-020-B-J9 x 5 in952.0 kW2-3.9120 VAC1-Phase
HFI-0905-030-F-J9 x 5 in952.1 kW2-3.9200 VAC1-Phase
HFI-0905-030-F-J9 x 5 in952.3 kW2-3.9208 VAC1-Phase
HFI-0905-030-F-J9 x 5 in952.5 kW2-3.9220 VAC1-Phase
HFI-0905-030-XX-J9 x 5 in952.7 kW2-3.9380 VAC1-Phase
HFI-0905-030-F-J9 x 5 in952.8 kW2-3.9230 VAC1-Phase
HFI-0905-030-XX-J9 x 5 in953.0 kW2-3.9400 VAC1-Phase
HFI-0905-030-F-J9 x 5 in953.0 kW2-3.9240 VAC1-Phase
HFI-0907-040-D-J9 x 7 in973.3 kW2-3.9200 VAC1-Phase
HFI-0909-055-L-J9 x 9 in993.4 kW2-3.9380 VAC1-Phase
HFI-0909-050-F-J9 x 9 in993.5 kW2-3.9200 VAC1-Phase
HFI-0907-040-D-J9 x 7 in973.6 kW2-3.9208 VAC1-Phase
HFI-0909-050-F-J9 x 9 in993.7 kW2-3.9208 VAC1-Phase
HFI-0909-055-L-J9 x 9 in993.8 kW2-3.9400 VAC1-Phase
HFI-0907-040-D-J9 x 7 in974.0 kW4-5.9220 VAC1-Phase
HFI-0909-050-F-J9 x 9 in994.2 kW4-5.9220 VAC1-Phase
HFI-0909-050-F-J9 x 9 in994.6 kW4-5.9230 VAC1-Phase
HFI-0909-050-F-J9 x 9 in995.0 kW4-5.9240 VAC1-Phase
HFI-0909-055-L-J9 x 9 in995.5 kW4-5.9480 VAC1-Phase
HFI-1105-040-D-J11 x 5 in1153.3 kW2-3.9200 VAC1-Phase
HFI-1107-050-F-J11 x 7 in1173.5 kW2-3.9200 VAC1-Phase
HFI-1107-055-L-J11 x 7 in1173.5 kW2-3.9380 VAC1-Phase
HFI-1105-040-D-J11 x 5 in1153.6 kW2-3.9208 VAC1-Phase
HFI-1107-050-F-J11 x 7 in1173.7 kW2-3.9208 VAC1-Phase
HFI-1107-055-L-J11 x 7 in1173.8 kW2-3.9400 VAC1-Phase
HFI-1105-040-D-J11 x 5 in1154.0 kW4-5.9220 VAC1-Phase
HFI-1107-050-F-J11 x 7 in1174.2 kW4-5.9220 VAC1-Phase
HFI-1107-050-F-J11 x 7 in1174.6 kW4-5.9230 VAC1-Phase
HFI-1109-070-F-J11 x 9 in1194.8 kW4-5.9200 VAC1-Phase
HFI-1107-050-F-J11 x 7 in1175.0 kW4-5.9240 VAC1-Phase
HFI-1109-070-F-J11 x 9 in1195.2 kW4-5.9208 VAC1-Phase
HFI-1111-088-L-J11 x 11 in11115.5 kW4-5.9380 VAC1-Phase
HFI-1107-055-L-J11 x 7 in1175.5 kW4-5.9480 VAC1-Phase
HFI-1109-070-F-J11 x 9 in1195.9 kW4-5.9220 VAC1-Phase
HFI-1111-088-L-J11 x 11 in11116.1 kW6-7.9400 VAC1-Phase
HFI-1109-070-F-J11 x 9 in1196.4 kW6-7.9230 VAC1-Phase
HFI-1109-070-F-J11 x 9 in1197.0 kW6-7.9240 VAC1-Phase
HFI-1111-088-L-J11 x 11 in11118.8 kW8-9.9480 VAC1-Phase
HFI-1305-045-L-J13 x 5 in1352.8 kW2-3.9380 VAC1-Phase
HFI-1305-045-L-J13 x 5 in1353.1 kW2-3.9400 VAC1-Phase
HFI-1305-050-F-J13 x 5 in1353.5 kW2-3.9200 VAC1-Phase
HFI-1305-050-F-J13 x 5 in1353.7 kW2-3.9208 VAC1-Phase
HFI-1305-050-F-J13 x 5 in1354.2 kW4-5.9220 VAC1-Phase
HFI-1309-068-L-J13 x 9 in1394.3 kW4-5.9380 VAC1-Phase
HFI-1305-045-L-J13 x 5 in1354.5 kW4-5.9480 VAC1-Phase
HFI-1305-050-F-J13 x 5 in1354.6 kW4-5.9230 VAC1-Phase
HFI-1309-068-L-J13 x 9 in1394.7 kW4-5.9400 VAC1-Phase
HFI-1307-070-F-J13 x 7 in1374.8 kW4-5.9200 VAC1-Phase
HFI-1309-070-F-J13 x 9 in1394.8 kW4-5.9200 VAC1-Phase
HFI-1305-050-F-J13 x 5 in1355.0 kW4-5.9240 VAC1-Phase
HFI-1309-070-F-J13 x 9 in1395.2 kW4-5.9208 VAC1-Phase
HFI-1307-070-F-J13 x 7 in1375.2 kW4-5.9208 VAC1-Phase
HFI-1309-070-F-J13 x 9 in1395.9 kW4-5.9220 VAC1-Phase
HFI-1307-070-F-J13 x 7 in1375.9 kW4-5.9220 VAC1-Phase
HFI-1311-090-Q-J13 x 11 in13116.2 kW6-7.9200 VAC3-Phase
HFI-1309-070-F-J13 x 9 in1396.4 kW6-7.9230 VAC1-Phase
HFI-1307-070-F-J13 x 7 in1376.4 kW6-7.9230 VAC1-Phase
HFI-1309-068-L-J13 x 9 in1396.8 kW6-7.9480 VAC1-Phase
HFI-1311-090-Q-J13 x 11 in13116.8 kW6-7.9208 VAC3-Phase
HFI-1311-110-L-J13 x 11 in13116.9 kW6-7.9380 VAC1-Phase
HFI-1309-070-F-J13 x 9 in1397.0 kW6-7.9240 VAC1-Phase
HFI-1307-070-F-J13 x 7 in1377.0 kW6-7.9240 VAC1-Phase
HFI-1311-110-L-J13 x 11 in13117.6 kW6-7.9400 VAC1-Phase
HFI-1311-090-Q-J13 x 11 in13117.6 kW6-7.9220 VAC3-Phase
HFI-1311-104-E-J13 x 11 in13117.9 kW6-7.9200 VAC1-Phase
HFI-1311-090-W-J13 x 11 in13118.1 kW8-9.9380 VAC3-Phase
HFI-1311-090-Q-J13 x 11 in13118.3 kW8-9.9230 VAC3-Phase
HFI-1311-104-E-J13 x 11 in13118.5 kW8-9.9208 VAC1-Phase
HFI-1311-090-Q-J13 x 11 in13119.0 kW8-9.9240 VAC3-Phase
HFI-1311-090-W-J13 x 11 in13119.0 kW8-9.9400 VAC3-Phase
HFI-1311-104-E-J13 x 11 in13119.5 kW8-9.9220 VAC1-Phase
HFI-1311-104-E-J13 x 11 in131110.4 kW10-11.9230 VAC1-Phase
HFI-1311-110-L-J13 x 11 in131111.0 kW10-11.9480 VAC1-Phase
HFI-1505-055-L-J15 x 5 in1553.4 kW2-3.9380 VAC1-Phase
HFI-1505-050-F-J15 x 5 in1553.5 kW2-3.9200 VAC1-Phase
HFI-1505-050-F-J15 x 5 in1553.7 kW2-3.9208 VAC1-Phase
HFI-1505-055-L-J15 x 5 in1553.8 kW2-3.9400 VAC1-Phase
HFI-1505-050-F-J15 x 5 in1554.2 kW4-5.9220 VAC1-Phase
HFI-1505-050-F-J15 x 5 in1554.6 kW4-5.9230 VAC1-Phase
HFI-1505-050-F-J15 x 5 in1555 kW4-5.9240 VAC1-Phase
HFI-1505-055-L-J15 x 5 in1555.5 kW4-5.9480 VAC1-Phase
HFI-1509-090-L-J15 x 9 in1595.6 kW4-5.9380 VAC1-Phase
HFI-1509-090-L-J15 x 9 in1596.3 kW6-7.9400 VAC1-Phase
HFI-1507-070-XX-J15 x 7 in1576.3 kW6-7.9380 VAC1-Phase
HFI-1509-100-F-J15 x 9 in1596.9 kW6-7.9200 VAC1-Phase
HFI-1507-070-XX-J15 x 7 in1577 kW6-7.9400 VAC1-Phase
HFI-1509-100-F-J15 x 9 in1597.5 kW6-7.9208 VAC1-Phase
HFI-1509-100-F-J15 x 9 in1598.4 kW8-9.9220 VAC1-Phase
HFI-1509-090-L-J15 x 9 in1599.0 kW8-9.9480 VAC1-Phase
HFI-1509-100-F-J15 x 9 in1599.2 kW8-9.9230 VAC1-Phase
HFI-1511-120-O-J15 x 11 in15119.9 kW8-9.9200 VAC3-Phase
HFI-1509-100-F-J15 x 9 in15910.0 kW10-11.9240 VAC1-Phase
HFI-1511-113-W-J15 x 11 in151110.2 kW10-11.9380 VAC3-Phase
HFI-1514-165-V-J15 x 14 in151410.3 kW10-11.9380 VAC3-Phase
HFI-1514-150-Q-J15 x 14 in151410.4 kW10-11.9200 VAC3-Phase
HFI-1511-120-O-J15 x 11 in151110.7 kW10-11.9208 VAC3-Phase
HFI-1514-150-Q-J15 x 14 in151411.2 kW10-11.9208 VAC3-Phase
HFI-1511-113-W-J15 x 11 in151111.3 kW10-11.9400 VAC3-Phase
HFI-1514-165-V-J15 x 14 in151411.4 kW10-11.9400 VAC3-Phase
HFI-1511-120-O-J15 x 11 in151112.0 kW12-13.9220 VAC3-Phase
HFI-1514-150-Q-J15 x 14 in151412.6 kW12-13.9220 VAC3-Phase
HFI-1514-150-Q-J15 x 14 in151413.7 kW12-13.9230 VAC3-Phase
HFI-1514-150-Q-J15 x 14 in151415.0 kW14-15.9240 VAC3-Phase
HFI-1514-165-V-J15 x 14 in151416.4 kW16-17.9480 VAC3-Phase
HFI-1907-088-L-J19 x 7 in1975.5 kW4-5.9380 VAC1-Phase
HFI-1907-088-L-J19 x 7 in1976.1 kW6-7.9400 VAC1-Phase
HFI-1909-090-Q-J19 x 9 in1996.2 kW6-7.9200 VAC3-Phase
HFI-1905-070-XX-J19 x 5 in1956.3 kW6-7.9380 VAC1-Phase
HFI-1909-090-Q-J19 x 9 in1996.8 kW6-7.9208 VAC3-Phase
HFI-1905-070-XX-J19 x 5 in1957.0 kW6-7.9400 VAC1-Phase
HFI-1909-090-Q-J19 x 9 in1997.6 kW6-7.9220 VAC3-Phase
HFI-1909-090-W-J19 x 9 in1998.1 kW8-9.9380 VAC3-Phase
HFI-1909-090-Q-J19 x 9 in1998.3 kW8-9.9230 VAC3-Phase
HFI-1911-135-V-J19 x 11 in19118.5 kW8-9.9380 VAC3-Phase
HFI-1907-088-L-J19 x 7 in1978.8 kW8-9.9480 VAC1-Phase
HFI-1909-090-Q-J19 x 9 in1999.0 kW8-9.9240 VAC3-Phase
HFI-1909-090-W-J19 x 9 in1999.0 kW8-9.9400 VAC3-Phase
HFI-1911-135-V-J19 x 11 in19119.4 kW8-9.9400 VAC3-Phase
HFI-1911-150-Q-J19 x 11 in191110.4 kW10-11.9200 VAC3-Phase
HFI-1911-150-Q-J19 x 11 in191111.2 kW10-11.9208 VAC3-Phase
HFI-1911-150-Q-J19 x 11 in191112.6 kW12-13.9220 VAC3-Phase
HFI-1914-205-V-J19 x 14 in191412.8 kW12-13.9380 VAC3-Phase
HFI-1911-135-V-J19 x 11 in191113.5 kW12-13.9480 VAC3-Phase
HFI-1911-150-Q-J19 x 11 in191113.7 kW12-13.9230 VAC3-Phase
HFI-1914-205-V-J19 x 14 in191414.2 kW14-15.9400 VAC3-Phase
HFI-1914-208-Q-J19 x 14 in191414.5 kW14-15.9200 VAC3-Phase
HFI-1911-150-Q-J19 x 11 in191115.0 kW14-15.9240 VAC3-Phase
HFI-1914-208-Q-J19 x 14 in191415.6 kW14-15.9208 VAC3-Phase
HFI-1914-208-Q-J19 x 14 in191417.5 kW16-17.9220 VAC3-Phase
HFI-1914-208-Q-J19 x 14 in191419.2 kW18-19.9230 VAC3-Phase
HFI-1914-205-V-J19 x 14 in191420.5 kW20-21.9480 VAC3-Phase
HFI-1914-208-Q-J19 x 14 in191420.8 kW20-21.9240 VAC3-Phase