PXH Series White Knight Pumps

PTFE/PFA Pumps Capable of 145°C (293°F) with Proximity Switch Controls

Overview

click+drag to rotate

PXH Series pumps are the ideal solution for high temperature and ultra-pure recirculation or delivery applications where proximity sensors are required for optimum systems control. These PTFE/PFA pumps are completely metal free and operate with proximity switches and external solenoid valve. They perform safely and reliably running continuously throughout their two-year warranty. They offer air supply pressures up to 5.5 Bar (80 psi) and operate in thermal cycling applications with fluid temperatures up to 145°C (293°F).

The pumps are available in three models, PXH030, PXH060 and PXH140, which are capable of maximum flow rates of 30, 60 and 140 lpm, respectively.

Features & Benefits

  • Process-safe PTFE/PFA flow paths
  • Leak-proof, machined design
  • PTFE heads with Buttress-Threads
  • No elastomer O-rings, no leaks, never retorque
  • No lubrication in shift mechanisms
  • No electric motors, which generate heat
  • Various liquid connection options
  • Safe, leak-free operation due to no-metal design
  • Minimal parts for durable design
  • Class 100 cleanroom assembly, testing, and packaging
  • Easy to install and service
  • Dual proximity sensors
  • Robust bellows offer supply pressure of 5.5 Bar (80 psi)
  • No preventative maintenance during two-year warranty
White Knight Ultra-Pure Teflon PTFE/PFA Pump Materials
Chemical Recirculation and Delivery 5.5 Bar (80 psi) Pressures
Pump Temperatures to 145 Celsius (293 Fahrenheit)
White Knight Proximity Switch Shift Method
White Knight Two-Year Warranty
CE Certification Mark

Operation

PXH Series pumps operate with proximity switches and solenoid valve that optimize stroke timing by shifting the bellows quickly and efficiently to increase durability.

Proximity-Controlled Pump Operations Diagram

Need shuttle valve or fiber optic sensors?

PSH Series pumps are controlled by shuttle valves.
PFH Series pumps are controlled with fiber optic sensors.

Supply Air

Exhaust Air

Ambient Air

Shift Signal

Liquid Suction

Liquid Discharge

Temperature Limits

PXH Series Air-Supply Fluid Temperature Limitations

Need Higher Temperatures?

PXU Series pumps are capable of temperatures up to 210°C (410°F).

Performance Curves

PXH030 Performance Curves

PXH030 Performance Curves

PXHSD030 Performance Curves

PXHSD030 Performance Curves

PXH060 Performance Curves

PXH060 Performance Curves

PXHSD060 Performance Curves

PXHSD060 Performance Curves

PXH140 Performance Curves

PXH140 Performance Curves

Configuration

Order NowGet Quote
Locate Distributors

Dimensions

PXH030 Dimensions

Dimensions: [mm] in

White Knight PXH030 Pump Dimensions
Download PXH030 Dimensions (PDF)

PXH060 Dimensions

Dimensions: [mm] in

White Knight PXH060 Pump Dimensions
Download PXH060 Dimensions (PDF)

PXH140 Dimensions

Dimensions: [mm] in

White Knight PXH140 Pump Dimensions
Download PXH140 Dimensions (PDF)

Specifications

Model
PXH030
PXH060
PXH140
Flow Rate*
24.3 LPM
6.42 GPM
63.8 LPM
16.85 GPM
137.8 LPM
36.40 GPM
Size of Air Connection
1/4" FNPT
1/4" FNPT
3/8" FNPT
Displacement Per Cycle*
0.077 liters
0.020 gal.
0.649 liters
0.050 gal.
0.500 liters
0.132 gal.
Cycles Per Minute*
390 max
366 max
247 max
Weight
3.62 kg
7.98 lbs.
5.88 kg
12.96 lbs.
17.20 kg
37.92 lbs.
Suction Lift*
1 m (3 ft.)
1 m (3 ft.)
1 m (3 ft.)
Sound Pressure**
69.54 dB(a)
75.56 dB(a)
68.60 dB(a)
82.12 dB(a)
74.81 dB(a)
76.91 dB(a)
Sound Power**
58.44 dB(a)
64.49 dB(a)
60.66 dB(a)
73.35 dB(a)
72.30 dB(a)
73.45 dB(a)
Max Temperature
145°C (293°F)
Max Pressure
5.5 Bar (80 PSI)
Fluid Path Materials
PTFE / PFA
Non-Fluid Path Materials
PTFE / PFA / SS
Stroke Detection Options
Proximity stroke detection
Leak Detection Options
Fiber optic with or without sensor, or conductivity
Electronic Control
Available
Model
PXH030
PXH060
PXH140

*May vary depending on configuration. Suction lift diminishes over time. Recommended installation level less than 3 ft. above source.