PSH Series White Knight Pumps

PTFE and PFA Pumps Capable of 145°C with On-Board Shuttle Valve

White Knight PSH Series Air-Operated Double-Bellows Pumps
PSH Specification Sheet

Owner's Manuals

PSH015 Owner’s ManualPSH030 Owner’s ManualPSH060 Owner’s ManualPSH140 Owner’s Manual

Exploded Views

PSH015 Exploded ViewPSH030 Exploded ViewPSH060 Exploded ViewPSH140 Exploded View

Rebuild Kits

PSH015 Rebuild KitPSH030 Rebuild KitPSH060 Rebuild KitPSH140 Rebuild Kit

CAD Models

PSH030 CAD ModelsPSH060 CAD Models

Ordering Instructions

PSH015 Ordering InstructionsPSH030 Ordering InstructionsPSH060 Ordering InstructionsPSH140 Ordering Instructions
Request QuoteLocate Distributors

Overview

click+drag to rotate

PSH Series pumps are the ideal solution for high temperature, ultra-pure recirculation and delivery applications. These PTFE and PFA pumps are completely metal free and operate with a unique shuttle valve that eliminates the need for complicated detents and manual resets. They perform safely and reliably running continuously throughout their two-year warranty. They offer air supply pressures up to 5.5 Bar (80 psi) and operate in thermal cycling applications with fluid temperatures up to 145°C (293°F). The pumps are available in four models, PSH015, PSH030, PSH060 and PSH140, which are capable of maximum flow rates of 15, 30, 60 and 140 lpm, respectively.

Features & Benefits

  • 100% Metal-Free
  • Process-safe PTFE and PFA flow paths
  • Leak-proof, machined design
  • PTFE heads with Buttress-Threads
  • No elastomer O-rings, no leaks, never retorque
  • No lubrication in shift mechanisms
  • No electric motors, which generate heat
  • Pneumatic Logic™ minimizes liquid pulsation and pump vibration
  • Various liquid connection options
  • Safe, leak-free operation due to no-metal design
  • Ceramic in air shuttle valve
  • Minimal parts for durable design
  • Class 100 cleanroom assembly, testing, and packaging
  • Easy to install and service
  • No preventative maintenance during two-year warranty
  • Robust bellows offer supply pressure of 5.5 Bar (80 psi)
  • Dead-head capable operation
White Knight Ultra-Pure PTFE and PFA Pump Materials
Chemical Recirculation and Delivery 5.5 Bar (80 psi) Pressures
Fluid Temperatures to 145 Celsius (293 Fahrenheit)
White Knight Pneumatic Shuttle Valve Shift Method
White Knight Two-Year Warranty
CE Certification Mark

Operation

PSH Series pumps feature White Knight’s Pneumatic Logic™, a detent-free shuttle valve design that improves performance and reliability by minimizing vibration, pulsation and wear.

Supply Air

Exhaust Air

Ambient Air

Liquid Suction

Liquid Discharge

Temperature Limits

Performance & Dimensions

PSH140 Performance Curves

*Graph is for reference only. Performance was measured utilizing 1/2 in (3/8 in ID) air line and 1-1/4 in (1-1/8 in ID) liquid lines with 1 ft flooded suction. Performance may vary in your system.

PSH140 Dimensions

Dimensions: [mm] in

Download PSH140 Dimensions (PDF)

PSH060 Performance Curves

*Graph is for reference only. Performance was measured utilizing 1/2 in (3/8 in ID) air line and 1-1/4 in (1-1/8 in ID) liquid lines with 1 ft flooded suction. Performance may vary in your system.

PSH060 Dimensions

Dimensions: [mm] in

Download PSH060 Dimensions (PDF)

PSHSD060 Performance Curves

*Graph is for reference only. Performance was measured utilizing 1/2 in (3/8 in ID) air line and 1-1/4 in (1-1/8 in ID) liquid lines with 1 ft flooded suction. Performance may vary in your system.

PSH060 Dimensions

Dimensions: [mm] in

Download PSH060 Dimensions (PDF)

PSH030 Performance Curves

*Graph is for reference only. Performance was measured utilizing 1/2 in (3/8 in ID) air line and 1-1/4 in (1-1/8 in ID) liquid lines with 1 ft flooded suction. Performance may vary in your system.

PSH030 Dimensions

Dimensions: [mm] in

Download PSH030 Dimensions (PDF)

PSHSD030 Performance Curves

*Graph is for reference only. Performance was measured utilizing 1/2 in (3/8 in ID) air line and 1-1/4 in (1-1/8 in ID) liquid lines with 1 ft flooded suction. Performance may vary in your system.

PSH030 Dimensions

Dimensions: [mm] in

Download PSH030 Dimensions (PDF)

PSH015 Performance Curves

*Graph is for reference only. Performance was measured utilizing 1/2 in (3/8 in ID) air line and 1-1/4 in (1-1/8 in ID) liquid lines with 1 ft flooded suction. Performance may vary in your system.

PSH015 Dimensions

Dimensions: [mm] in

Download PSH015 Dimensions (PDF)

PSHSD015 Performance Curves

*Graph is for reference only. Performance was measured utilizing 1/2 in (3/8 in ID) air line and 1-1/4 in (1-1/8 in ID) liquid lines with 1 ft flooded suction. Performance may vary in your system.

PSHSD015 Dimensions

Dimensions: [mm] in

Download PSH015 Dimensions (PDF)

Specifications

Model
PSH015
PSH030
PSH060
PSH140
Max Flow Rate*
13.4 lpm
3.54 gpm
22.8 lpm
6.02 gpm
58.3 lpm
15.40 gpm
118 lpm
31.3 gpm
Size of Air Connection
1/4-in FNPT
1/4-in FNPT
1/4-in FNPT
3/8-in FNPT
Displacement Per Cycle*
0.074 liters
0.019 gal
0.074 liters
0.019 gal
0.178 liters
0.047 gal
0.500 liters
0.132 gal
Cycles Per Minute*
216 max
333 max
348 max
254 max
Weight
4.6 kg (10.1 lb)
4.6 kg (10.1 lb)
7.3 kg (16.1 lb)
18.5 kg (40.9 lb)
Suction Lift*
1 m (3 ft)
1 m (3 ft)
1 m (3 ft)
1 m (3 ft)
Sound Pressure**
74.00 dB(a)
79.90 dB(a)
74.00 dB(a)
79.90 dB(a)
73.11 dB(a)
82.50 dB(a)
71.73 dB(a)
75.42 dB(a)
Sound Power**
63.01 dB(a)
69.90 dB(a)
63.01 dB(a)
69.90 dB(a)
64.29 dB(a)
74.11 dB(a)
70.46 dB(a)
75.27 dB(a)
Max Temperature
145°C (293°F)
Max Pressure
5.5 Bar (80 psi)
Fluid Path Materials
PTFE / PFA
Non-Fluid Path Materials
PTFE / PFA / ceramic
Stroke Detection Options
Fiber optic with or without sensor, or solid state pressure switch
Leak Detection Options
Fiber optic with or without sensor, or conductivity
Electronic Control
Available
Model
PSH015
PSH030
PSH060
PSH140

*May vary by configuration or system. Suction lift diminishes over time. Recommended installation level less than 3 ft above source.
**dB Level at 80 psi 50 CPM (top) and 80 psi maximum CPM (bottom). Sound Levels measured in accordance with ISO9614-2:1997.
***Dry-run capable PSHSD pumps require flooded suction and may have a reduced warranty. Contact White Knight for details.

Configuration